Worcester Bosch Boiler Error Codes: Common Faults & Fixes
A Worcester Bosch error code is a short letter-and-number code shown when the boiler detects a fault, commonly EA or 227 (flame not detected), C6 (fan speed), E9 (overheating limit tripped), A1 (pump fault) or D1 (return sensor). Note the code, check the pressure gauge, power and gas supply, and reset once if your manual allows. If the code returns, or you smell gas, stop and call a Gas Safe registered engineer.
In this post, we'll cover
- Key takeaways
- What's in this guide
- First: is this an emergency?
- Do this first, whatever the code
- The four Worcester Bosch codes people search for most
- Worcester Bosch fault code table
- How to reset a Worcester Bosch boiler
- Locking vs blocking errors, in plain English
- When to stop and call a Gas Safe engineer
- Carbon monoxide: the quiet one
- Worcester Bosch lockout at the worst moment?
Your Worcester Bosch is flashing EA, C6 or E9 and the heating has stopped. Here's what the common codes mean, what you can safely check, and when to leave it to a Gas Safe engineer.
Worcester Bosch boilers have a reputation for being solid, quiet workhorses. Which makes it all the more annoying when yours flashes EA at you on the coldest morning of the month and refuses to fire.
The thing to know is that Worcester Bosch codes are a bit different from some other brands. You will see letters like EA, C6, E9, A1 and D1, often with a three-digit cause code such as 227 or 224. They are the boiler's safety checks telling you what they found. A couple of them you can look at yourself. Most you shouldn't.
This guide goes through the common ones, what is safe to try, and how to tell a boiler that wants a quick check from one that wants an engineer.
Key takeaways
- EA and 227 usually mean the boiler could not detect a flame. Check gas and power; anything beyond that is for an engineer.
- C6 (fan), E9 (overheating), A1 (pump) and D1 (sensor) need a Gas Safe engineer if they persist.
- Worcester Bosch boilers can show locking errors (a flashing code, usually with a symbol) and blocking errors. They behave differently, so check your manual.
- Code meanings vary by model, including between Greenstar ranges.
- Gas smell or carbon monoxide symptoms: leave and call 0800 111 999.
What's in this guide
- Is this an emergency?
- Do this first
- The codes people search for most
- Worcester Bosch fault code table
- How to reset a Worcester Bosch
- Locking vs blocking errors, in plain English
- When to call an engineer
- Carbon monoxide
- FAQs
First: is this an emergency?
Smell gas? Act now, read later.
- Open doors and windows and leave the property.
- Don't switch lights or appliances on or off. No flames.
- If you can reach it safely, turn the gas off at the meter.
- Call the National Gas Emergency Service on 0800 111 999 (free, 24 hours) from outside.
No gas smell? Here is how we sort the codes below:
Level | What it means |
Green | A simple check you can do: gauge, power, thermostat, gas supply, a frozen condensate pipe, one reset. |
Amber | Fan, flue, sensor, pump, overheating or a repeating code. Stop and call a Gas Safe engineer. |
Red | Gas smell or carbon monoxide symptoms. Leave, call 0800 111 999. No troubleshooting. |
Do this first, whatever the code
- Photograph the display. Note the exact code (including any three-digit number) and your model name. An engineer will thank you.
- Check the pressure gauge. When the system is cold, it should sit at roughly 1 to 1.5 bar.
- Check the basics. Power on? Thermostat and timer calling for heat, with working batteries? Gas hob working? Credit on a prepayment meter?
- Is it freezing outside? A frozen condensate pipe can lock out many condensing boilers. Thaw it with warm (never boiling) water and restart.
- Reset once. If the code returns, stop and call an engineer.
Have boiler or home emergency cover? Call your provider before you book an engineer yourself. With Smart Cover, repairs arranged without our approval may not be covered.
The four Worcester Bosch codes people search for most
EA / 227: no flame detected
The boiler did not sense a flame after ignition, or lost it while running. It often appears as EA 227.
Try: check the gas supply is on, the hob works, a prepayment meter has credit and the boiler has power. In frost, check the condensate pipe too.
Stop if: you have done those checks and it returns. Igniter, electrode or lead problems need a Gas Safe engineer.
C6: fan speed
The fan is running too fast or too slow. The fan moves combustion gases out through the flue, so this is a safety matter.
Try: nothing beyond noting the code.
Stop: call a Gas Safe engineer. The fan lead, connector or fan may need replacing.
E9 / 224: temperature limiter tripped
The flow temperature, or a flue or maximum temperature thermostat, has overheated and cut out. It often shows as E9 with a cause code such as 224. Low pressure or poor circulation can contribute.
Try: check the pressure gauge (roughly 1 to 1.5 bar cold) and that radiator valves are open.
Stop if: it returns. A repeating E9 needs an engineer.
A1: pump fault
The pump may be stuck, running dry or have air in the system. On some models it can also hint at a leak.
Try: check pressure and look for obvious leaks.
Stop if: it persists. A stuck or failing pump needs a Gas Safe engineer.
Worcester Bosch fault code table
Worcester Bosch uses a mix of letter codes and numeric cause codes, depending on the model. These are the ones people see most. Confirm in your manual.
Type | Code | Usually means | Your move |
Flame and ignition | EA / 227 | Flame not detected, or flame lost | Green. Check gas and power; in frost, check the condensate pipe. Reset once. Repeats? Amber |
Fan and flue | C6 | Fan speed wrong | Amber. Engineer |
Safety | E9 / 224 | Temperature limiter or maximum temperature thermostat tripped (overheating) | Amber. Check pressure and radiator valves. Repeats? Engineer |
Pump | A1 | Pump stuck, running dry or air in the system | Amber. Check pressure and leaks. Persists? Engineer |
Sensors | D1 | Return sensor fault (short circuit or damage) | Amber. Engineer. Don't attempt a repair |
Pressure | 1017 | Low water pressure (on newer models) | Green. Top up to the preset pressure per your manual. Dropping again? Amber |
Display | FD | Reset button pressed by mistake (on some models) | Green. Press reset again |
Meanings are common interpretations and vary by model. Where your display shows a code not listed here, use the manual or ask an engineer.
How to reset a Worcester Bosch boiler
How you reset a Worcester Bosch depends on the type of error. A locking error (a flashing code, usually with a symbol) should only be reset after the fault has been put right. A blocking error usually shows no code on its own; pressing the return button can show the cause, and it clears once the problem is fixed. If you accidentally press reset and see FD, just press reset again.
Models differ, so follow your manual for the exact buttons. And the rule is once: if the code returns, see our wider guide to boiler error codes, or our checklist for a boiler that won't fire up.
Locking vs blocking errors, in plain English
This catches a lot of people out. A blocking error is the boiler pausing: it is waiting for something to change (a temperature, a pressure) and will often restart on its own. A locking error is the boiler shutting down and staying shut until the cause is dealt with and the boiler is reset.
Practically: if the boiler recovers by itself after a short wait, make a note of the code and mention it at your next service. If it locks out and stays out, work through the checks above, reset once, and call a Gas Safe engineer if it returns.
When to stop and call a Gas Safe engineer
Boilers are sealed gas appliances, and gas work in the UK must be done by someone on the Gas Safe Register. Call when:
- a code returns after one reset, or a different one replaces it
- it relates to the fan, flue, sensors, pump, overheating or gas valve
- there is leaking water, banging or whistling, soot or black marks around the boiler
- the flame, if you can see it, looks mostly yellow or orange rather than steady blue
- fixing it would mean taking the casing off. Always.
Check the ID. Every registered engineer carries a Gas Safe ID card with a photo, and you can verify them on the Gas Safe Register website. If you have boiler cover, call your provider first so they can arrange the engineer.
Carbon monoxide: the quiet one
Carbon monoxide has no smell, colour or taste. Symptoms feel like flu without a temperature: headaches, dizziness, nausea, tiredness. If several people at home feel unwell and it eases when you're out, take it seriously. Fit an audible CO alarm near the boiler and in bedrooms, test it, and if it sounds, open windows, leave and call 0800 111 999.
Keeping the boiler healthy helps too: an annual boiler service, bleeding radiators that are cold at the top, and a glance at the gauge once a month. If you have Smart Cover boiler cover, your boiler must have been serviced in the 12 months before a breakdown claim. If the codes keep changing on an older boiler, it's worth calmly weighing up whether to keep repairing it or replace it. A Gas Safe engineer can give you an honest view of its condition.
Worcester Bosch lockout at the worst moment?
Smart Cover boiler cover and home emergency cover are there for the covered breakdowns the checklist can't fix. Report an emergency any time on our 24/7 Emergency Helpline, 03333 449 247, and we'll arrange an engineer from our UK network for covered faults. For claims and other enquiries, call 03333 449 559.
Before you rely on cover, know the key terms:
- Cover is for gas boilers only. Oil, LPG and electric boilers are not covered.
- Your boiler must have been serviced in the 12 months before a breakdown claim.
- There is a waiting period from the start of your policy: 14 days for homeowner policies and 28 days for landlord policies.
- Claims are paid up to the claim limit on your policy schedule.
- Exclusions include wear and tear, sludge and limescale, faults that existed before your policy started, and repairs arranged without contacting us first.
See boiler cover or home emergency cover. Read the policy documents and IPID for full terms. Cover helps with repair costs for covered breakdowns. A gas smell or CO symptoms are always an emergency call to 0800 111 999 first.
Official sources
- Gas Safe Register: find and check registered engineers
- HSE: gas safety in the home
- National Gas Emergency Service: 0800 111 999
- Your Worcester Bosch manual or worcester-bosch.co.uk for model-specific fault code lists
Keep reading
- Vaillant Boiler Error Codes:F22, F28, F75 and more
- Baxi error codes: E133, E118 and more
- Glow-worm Boiler Error Codes: Complete Guide
General information only. This guide isn't a substitute for your boiler manufacturer's instructions or advice from a Gas Safe registered engineer. Fault code meanings vary by model. Smart Cover is not affiliated with Worcester Bosch. This is a marketing communication. Cover is subject to policy terms, limits and exclusions. Reviewed 18 November 2026.
Smart-Cover Insurance Services, Smart Cover and Smart Cover 247 are trading names of Smart-Cover Direct Limited (FRN 600428), an Appointed Representative of City and Commercial Limited (FRN 314346), which is authorised and regulated by the Financial Conduct Authority. The Financial Ombudsman Service can be contacted at www.financial-ombudsman.org.uk.