Offer

50% Off for 12 Months on Home Emergency Cover Plans

Limited Time Offer - Expires 21 December 2026

Ariston Boiler Fault Codes: Complete Error Code Guide

Connor Reviewed by Connor
Ariston combi boiler display showing fault code 108 with the pressure gauge below reading low
In short

An Ariston fault code is the boiler telling you its safety checks found a problem. The most common are 108 (low water pressure), 5P1 or 5P2 (failed to light, often read as SP1 or SP2), 501 (no flame detected) and 301 to 307 (circuit board faults). Check the pressure gauge, power and gas supply, fix the cause and reset once. If the code comes back, or you smell gas, call a Gas Safe registered engineer.

In this post, we'll cover

It's a cold morning, the radiators are stone cold and your Ariston is showing 108, or something that looks like SP1. Most boiler brands use F or E codes. Ariston mostly shows plain numbers, which can look random if you've never seen one before. 

They aren't random. Some are simple enough to deal with yourself, and low pressure (108) is the classic example. Others are strictly a job for a Gas Safe registered engineer. This guide helps you tell the two apart. Code meanings vary between Ariston models, so treat this as a first guide and your manual as the final word. 

Smell gas? Do this first 

  • Open doors and windows.  
  • Don't switch lights or appliances on or off, and don't use any naked flames. 
  • If you can reach it safely, turn the gas off at the meter. 
  • Once you're outside, call the National Gas Emergency Service on 0800 111 999. It's free and open 24 hours. 
  • Leave the property immediately. 

The same applies if anyone has carbon monoxide symptoms. We cover those further down. 

Do this first, whatever the code 

 
  1. Check the pressure gauge. When the system is cold it usually sits at around 1 to 1.5 bar. 
  2. Check the basics. Is the power on? Is the thermostat calling for heat, with working batteries? Does your gas hob light? Is there credit on a prepayment meter? 
  3. Is it freezing outside? A frozen condensate pipe can stop many condensing boilers. Pour warm (never boiling) water over the outside pipe, then restart. 
  4. Photograph the display. Note the exact code and your boiler's model name. It saves time when you speak to an engineer. 
  5. Reset once. If the code comes back, stop and call an engineer. 

The Ariston codes people search for most 

108: Low water pressure- Filling required 

The pressure has dropped too low and the boiler has locked out, so restarting alone won't fix it. Top up with the filling loop until the gauge reads around 1 to 1.5 bar, close the valves fully, then restart. Your manual shows the exact steps for your model. 

If the pressure keeps dropping, or drops suddenly, there may be a leak somewhere in the system. That's the point to call a Gas Safe engineer. 

5P1 or 5P2 (often read as SP1 or SP2): Failed to light 

5P1 means First ignition attempt failed. 

5P2 means Second ignition attempt failed. 

The boiler tried to light and couldn't. The display shows 5P1 or 5P2, which is why so many people search for SP1 or SP2. Causes range from a gas supply problem to faulty ignition parts. 

Check the pressure is normal, the thermostat is calling for heat, your other gas appliances work and any prepayment meter has credit. Then reset once. If it comes back, the ignition parts and burner need a Gas Safe engineer. 

501: No flame detected 

The boiler tried to ignite but didn't detect a flame. Apart from checking your gas supply is on, there's nothing here for you to fix. Call a Gas Safe engineer. 

301 to 307: Circuit board faults 

Codes in the 300s point to the printed circuit board (PCB), which is the boiler's control centre. Sometimes it's a loose connection and sometimes the board needs replacing. Either way, it's an engineer job. Switch the boiler off if it starts behaving oddly. 

600s: Air, fan and flue codes 

Codes in the 600 range relate to the air inlet, fan or flue, the parts that safely carry fumes out of your home. Don't open the boiler or try to clean the fan yourself. Call a Gas Safe engineer. 

You may see A41 and E43 listed online as Ariston fan and air pressure switch codes. They aren't in the Ariston fault code lists we checked, and A41 is used by another boiler brand, so check your manual before acting on either one. 

Ariston fault code table 

Code 

Usually means 

What you can do 

108 

Low water pressure (boiler locks out) 

Repressurise as your manual shows, then restart. Keeps dropping? Call an engineer 

5P1 / 5P2 

Failed to light (ignition failure) 

Check pressure, thermostat, gas supply and meter credit. Reset once. Comes back? Call an engineer 

501 

No flame detected 

Check the gas supply is on, then call an engineer 

301 to 307 

Circuit board (PCB) fault 

Call an engineer 

600s 

Air inlet, fan or flue fault 

Call an engineer. Don't open the boiler 

These are common meanings and they vary by model. If your code isn't here, check your manual or ask an engineer. 

How to reset an Ariston boiler 

Only reset once you've dealt with the cause. Resetting with a fault still there won't fix it and can make things worse. So repressurise first for 108, or run through the basic checks for an ignition code, then reset once. 

The method varies by model. On many you press and hold the reset button for a few seconds, but check your manual. If the code returns, stop and work through our checklist for a boiler that won't fire up before you call an engineer. 

Why Ariston codes catch people out 

Ariston uses numbers where most brands use letters, so searching for "F22" or "E119" will take you to the wrong manufacturer. And 5P1 is very easy to misread as SP1. Searching for the code plus "Ariston" and your model name gets you to the right answer faster. 

Got a different boiler? Our main guide to boiler error codes covers the other big brands. 

If you've got a Potterton, we also have a separate guide to Potterton error codes. 

When to call a Gas Safe engineer 

Boilers are gas appliances, and in the UK gas work must be done by someone on the Gas Safe Register. Call an engineer if: 

 
  • a code comes back after one reset, or a different code replaces it 
  • it relates to the fan, flue, sensors, pump, overheating or gas valve 
  • you see leaking water, soot or black marks, or hear banging or whistling 
  • the flame, if you can see it, looks yellow or orange instead of a steady blue 
  • fixing it would mean taking the casing off 

Every registered engineer carries a Gas Safe ID card with their photo, and you can check them on the Gas Safe Register website. 

Carbon monoxide: the one you can't smell 

Carbon monoxide has no smell, colour or taste. Symptoms can feel like flu without a temperature: headaches, dizziness, nausea and tiredness. If several people at home feel unwell and it eases when you go out, take it seriously. 

Fit an audible CO alarm and test it regularly. If it sounds, open windows, get everyone out and call 0800 111 999. 

Keeping your Ariston healthy 

A yearly service by a Gas Safe engineer helps catch problems before they turn into a lockout. Between services, glance at the pressure gauge once a month and bleed any radiators that are cold at the top. 

Servicing also matters if you have boiler cover. Smart Cover boiler claims need the boiler to have been serviced in the 12 months before you claim. Smart Cover offers an optional boiler service, but it's a separate product and not part of the insurance. 

Can boiler cover help with an Ariston fault? 

Smart Cover boiler cover is insurance for sudden, unexpected breakdowns of a gas boiler. If you make a valid claim, our 24/7 helpline arranges an approved engineer, and the policy helps pay for the call-out, parts and labour up to £500 or £1,000 per claim, depending on your plan. Cover is subject to terms, conditions, limits and exclusions, and you pay any excess and anything above the claim limit. 

A few conditions matter for fault codes. Your boiler must have been serviced in the last 12 months. Faults that started before your policy, or in the first 14 days (28 days for landlord policies), aren't covered, so a code that's already showing wouldn't be covered by a new policy. Cover is for gas boilers up to 60kW in mainland England, Wales and Scotland. 

Some causes behind fault codes are excluded too. These include general maintenance, removing sludge or scale, the boiler flue, intermittent or recurring faults, and breakdowns where you've only lost hot water. If an engineer visits and finds no fault, the claim is declined and the call-out charge is still payable. 

Smart Boiler covers the boiler and internal gas supply pipe. Faults in the wider central heating system need a higher plan, and our home emergency cover plans build up from there to plumbing, drainage and electrics. 

For a closer look at limits and exclusions, see our guide to boiler breakdown insurance costs and exclusions. 

General information only. This guide isn't a substitute for your boiler manufacturer's instructions or advice from a Gas Safe registered engineer. Fault code meanings vary by model. Smart Cover is not affiliated with Ariston. 

 
 
 
 
 
 
 
 

Smart-Cover Insurance Services, Smart Cover and Smart Cover 247 are trading names of Smart-Cover Direct Limited (FRN 600428), an Appointed Representative of City and Commercial Limited (FRN 314346), which is authorised and regulated by the Financial Conduct Authority. The Financial Ombudsman Service can be contacted at www.financial-ombudsman.org.uk.

Frequently asked questions

What does 108 mean in an Ariston boiler?

108 means the water pressure is too low and the boiler has locked out. Top up with the filling loop to around 1 to 1.5 bar, following your manual, then restart. If the pressure keeps dropping, there may be a leak, so call a Gas Safe engineer.

What does SP1 or 5P1 mean on an Ariston boiler?

The display shows 5P1 or 5P2, often read as SP1 or SP2. It means the boiler failed to light. Check the pressure, thermostat, gas supply and any prepayment meter, then reset once. If it comes back, call a Gas Safe registered engineer.

What does 501 mean in an Ariston boiler?

501 means the boiler tried to ignite but didn't detect a flame. Check your gas supply is on. Beyond that, it needs a Gas Safe engineer.

How do I reset an Ariston boiler?

Deal with the cause first, for example by repressurising for 108. Then press and hold the reset button as your manual describes, and do it once. If the code returns, stop and call a Gas Safe registered engineer.

Will boiler cover pay to fix an Ariston fault code?

It can help with a sudden breakdown of a gas boiler that happens after your policy starts, subject to terms, conditions, limits and exclusions, including the claim limit and any excess. The boiler must have been serviced in the last 12 months. Faults that